AC5227

AC5227

Produktcode: AirBox 2x3/2 2DI IP67
Marke: IFM
  • For the decentralized triggering of cylinders and valve actuators
  • Combination of AS-i I/O module and solenoid valve
  • High energy efficiency due to decentralized application near the actuator
  • Reduced installation and wiring complexity
  • Easy toolless installation
Application field installation
Medium temperature [°C] -10...50
Operating voltage [V] 26.5...31.6 DC
Max. current consumption from AS-i [mA] 180
Integrated watchdog yes
Number of inputs and outputs Number of digital inputs: 2; Number of pneumatic outputs: 2
Number of digital inputs 2
Input circuit of digital inputs PNP
Sensor supply of the inputs AS-i
Voltage supply [V] 20...30; (via flat cable)
Max. total current rating of inputs [mA] 100
Input current High [mA] 6...10
Input current low [mA] 0...2
Switching level high [V] > 11
Digital inputs protected against short circuits yes
Number of pneumatic outputs 2
Actuator supply outputs AS-i
Ambient temperature [°C] -10...55
Protection IP 67
EMC
EN 50295
IEC 61000-6-2
MTTF [years] 321
AS-i version 2.11; 3.0
AS-i addressing Addressing socket
Extended addressing mode no
AS-i profile S-3.F.F
AS-i I/O configuration [hex] 3
AS-i ID code [hex] F.F
Data bits
Data bit D0 D1 D2 D3
Input 1 2 3 4
Socket I-1 I-2 - -
Pin 2+4 2+4 - -
pneumatic output - - 2 4
Weight [g] 355.9
Type of mounting quick mounting
Material PA; POM; Piercing contacts: CuSn6 nickel-plated and tin-plated
Pneumatic system 2 x 3/2-way slide valves (free from overlapping)
Operating pressure range [bar] 2...8
Operating pressure range [MPa] 0.2...0.8
Operating pressure range [psi] 29...116
Air flow at 6/5 bar [l/min] 500
Permissible compressed air non-lubricated compressed air class 6-3-1; lubricated compressed air class 6-3-4
Manual override pressing/releasing or pressing/turning/locking
Tube fittings 8 mm
Exhaust exhaust can be discharged through tube connection
Display
Power LED, green
errors LED, red
Function LED, yellow
Module connection Flat cable
Items supplied
lower part
Accessories (optional)
Mounting plate:, E74999
Module lower part:, E75000
Protective cap: M12, E73004
sealing plug:, E75231
Silencer:, E75232
Push-in L-fitting:, E75228
Push-in T-fitting:, E75227
Remarks
If not pneumatically operated, E75231 sealing plug must be inserted.
Avoid ingress of dirt and dust.
Do not connect any of the following points to an external potential:
L-, L+, I-1, I-2
The connections are electrically connected with the AS-i cable.
Please see the notes on compressed air and EMC/ESD under "Downloads"
Pack quantity 1 pcs.
quick mounting technology for AS-i flat cable: ; three selectable directions
Connector: M12; coding: A
Pneumatic symbol
2 x 3/2-way slide valves (free from overlapping)

AC5227 Dokümanları

Dateinamen Download-Link
AC5227.pdf Herunterladen

Ein Angebot bekommen